Products ALWO V Open-Face Dry-Filter Spray Booth
The ALWO V open-face dry-filter spray booth is a modular extraction wall for capturing paint and coating overspray. Its cold-formed galvanised-sheet-steel panels are mechanically assembled, and the wall size is selected according to the coated parts and working area.
A centrifugal fan installed on the roof, behind or beside the extraction wall creates the required negative pressure. Air is drawn from the spraying zone towards the filter face, limiting overspray dispersion when capture velocity and equipment position are correctly designed.
These stages are intended for overspray particulate, not solvent-vapour removal. Filtered air can be exhausted outdoors according to the project and applicable requirements; VOC reduction may require a separate activated-carbon system sized for the chemical composition, concentration and airflow.
The ALWO V range includes extraction walls from 2 to 5 m wide with maximum fan airflow from 7,000 to 20,200 m³/h. Actual operating airflow must account for filters, ductwork, filter loading and the total pressure loss of the installation.
Fan selection, air discharge, earthing, electrical equipment, fire prevention and filter replacement must be defined for the coating products being used. Loaded filters must be handled according to the safety data sheets and applicable regulations.
| Model | Dimensions L × W × H (mm) | Total pressure (mm H₂O) | Maximum fan airflow (m³/h) | Installed fan | Duct diameter (mm) |
|---|---|---|---|---|---|
| ALWO V20 | 2000 × 800 × 2200 | 43 | 7,000 | ATDG 450 | Ø 280 |
| ALWO V25 | 2500 × 800 × 2200 | 66 | 8,500 | ATDG 500 | Ø 350 |
| ALWO V30 | 3000 × 800 × 2200 | 73 | 10,800 | ATDG 535 | Ø 400 |
| ALWO V40 | 4000 × 800 × 2200 | 108 | 14,200 | ATDG 560 | Ø 420 |
| ALWO V50 | 5000 × 800 × 2200 | 66 | 20,200 | 2 × ATDG 535 | Ø 450 |






with extensive expertise

ISO 9001:2016

since 1999
Quick access to ALWO content
Type at least 3 characters to see results.